![Silicon Laboratories Si475X Series Скачать руководство пользователя страница 117](http://html1.mh-extra.com/html/silicon-laboratories/si475x-series/si475x-series_programming-manual_1272036117.webp)
AN543
Rev. 0.9
117
Property 0x2100 FM_NB_DETECT_THRESHOLD
The FM_NB_DETECT_THRESHOLD property sets the threshold for detecting impulses in dB above the noise
floor. The noise blanker can be disabled by setting the noise blanker detect threshold to 0.The CTS bit (and
optional interrupt) is set when it is safe to send the next command. This property may only be set or read in
powerup mode.
Default: 18
Units: dB
Property 0x2101 FM_NB_INTERVAL
The FM_NB_INTERVAL property sets the interval that original samples are replaced by interpolated clean
samples. The noise blanker can be disabled by setting the noise blanker detect threshold to 0.The CTS bit (and
optional interrupt) is set when it is safe to send the next command. This property may only be set or read in
powerup mode.
Default: 5
Units: none
FM_NB_DETECT_THRESHOLD
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
DETECT_THRESHOLD[15:0]
0x0012
Bit
Name
Function
15:0
DETECT_THRESHOLD[15:0]
Sets the threshold for detecting impulses in dB above the
noise floor.
Default is 18 dB
Range is 0–90 dB.
To disable the noise blanker, set the DETECT_THRESH-
OLD to 0.
FM_NB_INTERVAL
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
NB_INTERVAL[15:0]
0x0005
Bit
Name
Function
15:0
NB_INTERVAL[15:0]
Sets the interval in number of audio samples that original sam-
ples are replaced by interpolated clean samples.
Default is 5.
Range is 1–20.