Property 0x2117 FM_NB_CIMP_IMPDET
The FM_NB_CIMP_IMPDET property sets the noise blanker impulse detection threshold to replace property
0x2100 and 0x2105 when continuous impulses are detected. The CTS bit (and optional interrupt) is set when it is
safe to send the next command. This property may only be set or read in powerup mode.
Si475x-A40 and earlier: this property is not available.
Si475x/5xC-A55, Default is: 0x400A.
Property
0
x2118 FM_NB_CIMP_MPX_INTV
Th
e FM_NB_CIMP_MPX_INTV property sets the MPX noise blanker interval when continuous impulses are
detected replacing property 0x2101. The CTS bit (and optional interrupt) is set when it is safe to send the next
command. This property may only be set or read in powerup mode.
Si475x-A40 and earlier: This property is not available
Si475x/5xC-A55, Default: 0x0A0A
Unit: ms
FM_NB_CIMP_IMPDET
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
WEAK[7:0]
NORM[7:0]
0x40
0x0A
Bit
Name
Function
15:8
WEAK[7:0]
Sets the MPX noise blanker threshold at weak signal case replacing prop-
erty 0x2105 when continuous impulses are detected. the scale of this field
is property 0x2105>>8.
Si475x/5xC-A55, Default is 0x40. Range is 0 ~ 255.
7:0
NORM[7:0]
Sets the MPX noise blanker threshold at normal signal case replacing prop-
erty 0x2100 when continuous impulses are detected.
Si475x/5xC-A55, Default is 0x0A. Range is 0 ~ 255
.
FM_NB_CIMP_HICUT_FREQ
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
INTV[15:0]
0x0A0A
Bit
Name
Function
15:0
INTV[15:0]
MPX blanker interval when continuous impulses are detected, high Byte is
for strong signal case, low Byte is for weak signal case.
Si475x/5xC-A55, Default is 0x0A0A, Range is 0 ~ 32767.