![Silicon Laboratories Si475X Series Скачать руководство пользователя страница 254](http://html1.mh-extra.com/html/silicon-laboratories/si475x-series/si475x-series_programming-manual_1272036254.webp)
A N 5 4 3
254
Rev. 0.9
Property 0x2203 AM_CHBW_SQ_WIDENING_TIME (Si4754/55/56/57 Only)
The AM_CHBW_SQ_WIDENING_TIME property sets the Channel Filter Bandwidth widening time based on
max(IQSNR,SNR). The CTS bit (and optional interrupt) is set when it is safe to send the next command. This
property may only be set or read in powerup mode.
Default: 2048
Units: ms
Property 0x2204 AM_CHBW_SQ_NARROWING_TIME (Si4754/55/56/57 Only)
Th
e AM_CHBW_SQ_NARROWING_TIME property sets the Channel Filter Bandwidth narrowing time based on
max(IQSNR,SNR). The CTS bit (and optional interrupt) is set when it is safe to send the next command. This
property may only be set or read in powerup mode.
Default: 16
Units: ms
AM_CHBW_SQ_WIDENING_TIME
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
WIDENING_TIME[15:0]
0x0800
Bit
Name
Function
15:0
WIDENING_TIME[15:0]
Sets the max(IQSNR,SNR) based Channel Filter Bandwidth
widening time. Default is 2048 ms.
Range is 1–32767 ms.
AM_CHBW_SQ_NARROWING_TIME
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
NARROWING_TIME[15:0]
0x0010
Bit
Name
Function
15:0
NARROWING_TIME [15:0]
Sets the max(IQSNR,SNR) based Channel Filter Bandwidth
narrowing time. Default is 16 ms.
Range is 1–32767 ms.