A N 5 4 3
184
Rev. 0.9
Property 0x3709 FM_HIBLEND_MULTIPATH_CUTOFF_FREQ
The FM_HIBLEND_MULTIPATH_CUTOFF_FREQ property sets the maximum and minimum cutoff frequency
based on Multipath (set by Property 0x3708) on the HIBLEND engine. You can force a constant cutoff frequency
value by setting FREQ_MAX and FREQ_MIN to the same value. To disable the HIBLEND based on Multipath, set
FREQ_MAX = FREQ_MIN = 180 (0xB4). The CTS bit (and optional interrupt) is set when it is safe to send the next
command. This property may only be set or read in powerup mode.
Si475x-A40 and earlier, Default: 0xB41E
Si475x/5xC-A55, Default: 0x6419
Units: 100 Hz
Property 0x370A FM_HIBLEND_MULTIPATH_ATTACK_TIME
The FM_HIBLEND_MULTIPATH_ATTACK_TIME property sets the transition time for which the HIBLEND
mitigation engine lowers the cutoff frequency based on Multipath. The CTS bit (and optional interrupt) is set when it
is safe to send the next command. This property may only be set or read in powerup mode.
Si475x-A40 and earlier, Default: 4
Si475x/5xC-A55, Default: 100
Units: ms
FM_HIBLEND_MULTIPATH_CUTOFF_FREQ
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FREQ_MAX[7:0]
FREQ_MIN[7:0]
0x64
0x19
Bit
Name
Function
15:8
FREQ_MAX[7:0]
Sets the maximum cutoff frequency. Si475x/5xC-A55, Default is 10 kHz.
Range is 0–18 kHz.
7:0
FREQ_MIN[7:0]
Sets the minimum stereo separation. Si475x/5xC-A55, Default is 2.5 kHz.
Range is 0–18 kHz.
FM_HIBLEND_MULTIPATH_ATTACK_TIME
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
ATTACK[15:0]
0x0064
Bit
Name
Function
15:0
ATTACK[15:0]
Sets the transition time for which the HIBLEND mitigation engine
decreases the cutoff frequency based on Multipath.
Si475x/5xC-A55, Default is 100 ms. Range is 1–32767 ms.