Filling Empty Server System Bays
A filler panel, drive blank, or empty drive carrier must be installed into an empty drive
bay. To access the drive bays, remove the front bezel. For instructions, see
“Removing the
Front Bezel”
. With the bezel removed, install the appropriate panel(s), blank, or empty
hard drive bay(s) as described below.
•
If you do not have an optical drive installed in the slimline bay, install the slimline
filler panel.
•
Install empty hard drive carriers into any remaining empty hard drive bays.
Installing and Removing the PCI Riser Assembly
Removing the PCI Riser Assembly
To remove the PCI riser assembly, use the following instructions.
1. Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information”
.
2. Power down the server and unplug all peripheral devices and the AC power
cable(s).
3. Remove the server system cover. For instructions, see
“Removing the System
Cover”
.
4. Remove the processor air duct by lifting straight up.
5. Disconnect any cables attached to any add-in cards.
6. Grasp both riser latches with thumb and forefinger (see letter “A”), and pull up to
release riser assembly.
7. Lift riser assembly straight up (see letter “B”).