![Silicon Graphics Altix XE210 Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/silicon-graphics/altix-xe210/altix-xe210_user-manual_1271638054.webp)
38
SGI
®
Altix
®
XE210 User’s Guide
Installing a Slimline Optical Drive
1. Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information”
.
2. Power down the server and unplug all peripheral devices and the AC power
cable(s).
3. Remove the front bezel. For instructions, see
“Removing the Front Bezel”
.
4. Remove the server system cover. For instructions, see
“Removing the System
Cover”
.
5. Insert the interposer board into the optical drive.
6. Obtain the optical drive and the drive tray.
7. Align the two holes on the left edge of the optical drive and interposer board with
the two metal tabs in the tray as shown in
Figure 31
(see letter “A”).
8. Lower the opposite side of the optical drive into the tray until it clicks into place
(see letter “B”).
Figure 31. Installing an Optical Drive into the Drive Tray
9. Screw the interposer board into the carrier.
10. Insert the optical drive tray assembly into the server system as shown in
Figure 32
.
11. Make sure that the back end of the interposer board plugs into the matching socket
on the backplane.
12. Verify that the blue release lever on the tray locks into place.
TP02147
A
B