AG03/1
Commissioning English
AG03/1 · Date
23.07.2019 · Art.
No.
86426 · Mod.
status
179/19
39
5 Commissioning
Latch-up effects
Output stage of the driver is damaged.
`
The operating voltage of the device must be switched on together with
the downstream electronics unit (e.g. control).
Please carefully read the information on the actuator's mechanical and
electrical connection. This will ensure a trouble free commissioning and
operation.
Before operation, please check again:
•
that the supply voltage's polarity is correct.
•
correct connection of cable and signal lines.
•
secure actuator fixation on the hollow shaft.
Accessing the DIP switch, battery compartment and touch keys
Actuator failure (
Improper installation of the cover
15
leads to loss of the protection class.
`
The screws
14
with loss protection
21
and light guide
20
must fit cor-
rectly in the cover
15
.
`
Ensure that the O-ring
16
fits correctly in the groove.
`
Fibre optic cables must be seated in the holes provided in the housing.
`
Make settings in the setup mode only.
14
Screw
15
Cover
16
O-ring
20
Light guide
21
Loss protec-
tion
Fig. 9: Removal of cover
WARNING
WARNING