AG03/1
Commissioning English
AG03/1 · Date
23.07.2019 · Art.
No.
86426 · Mod.
status
179/19
42
This is illustrated in the following table:
SW1
[2
0
]
SW2
[2
1
]
SW3
[2
2
]
SW4
[2
3
]
SW5
[2
4
]
SW6
[2
5
]
SW7
[2
6
]
set slave
address
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1!
ON
OFF
OFF
OFF
OFF
OFF
OFF
1
OFF
ON
OFF
OFF
OFF
OFF
OFF
2
ON
ON
OFF
OFF
OFF
OFF
OFF
3
..
..
..
..
..
..
..
..
OFF
OFF
ON
ON
ON
ON
ON
124
ON
OFF
ON
ON
ON
ON
ON
125
OFF
ON
ON
ON
ON
ON
ON
126
ON
ON
ON
ON
ON
ON
ON
127
Address setting SIKONETZ5
The DIP switch settings are read in only during switching on voltage sup-
ply. Changing the slave address during operation has no effect.
The slave address is entered via switches 1 - 7 in binary format. The setting
of address 127 is internally set into address 126.
This is illustrated in the following table:
SW1
[2
0
]
SW2
[2
1
]
SW3
[2
2
]
SW4
[2
3
]
SW5
[2
4
]
set slave
address
OFF
OFF
OFF
OFF
OFF
0
ON
OFF
OFF
OFF
OFF
1
OFF
ON
OFF
OFF
OFF
2
..
..
..
..
..
..
OFF
ON
ON
ON
ON
30
ON
ON
ON
ON
ON
31
Setting the SIKONETZ5 baud rate
Enter the baud rate in the binary format via switches 6 - 7. This is illus-
trated in the following table:
SW6
SW7
Baud rate set
OFF
OFF
57600 Baud
ON
OFF
115200 Baud
OFF
ON
19200 Baud
ON
ON
57600 Baud
NOTICE