AG03/1
Battery change English
AG03/1 · Date
23.07.2019 · Art.
No.
86426 · Mod.
status
179/19
44
6.2 Operating states
Refer to the manual for more detailed information about failures and
warnings.
6.3 Changing the battery
Actuator failure (
)
Improper installation of the cover
15
leads to loss of the protection class.
`
The screws
14
with loss protection
21
and light guide
20
must fit cor-
rectly in the cover
15
.
`
Ensure that the O-ring
16
fits correctly in the groove.
`
Fibre optic cables must be seated in the holes provided in the housing.
`
Make settings in the setup mode only.
14
Screw
15
Cover
16
O-ring
18
Battery
19
Holder
20
Light guide
21
Loss protec-
tion
Fig. 12: Changing batteries
Preparation:
1. Connect actuator to supply voltage.
2. Place the replacement battery ready (see chapter
).
3. Place a Phillips screwdriver ready (e. g . PH 1).
Dismounting (see
1. The battery compartment is situated behind the cover of the cover
15
.
2. Remove the cover
15
incl. the plugged screws
14
with loss protection
21
and light guide
20
.
3. Use your fingernail to bend the battery slightly outward.
4. Grasp the used battery
18
at the upper edge and pull out axially.
5. For the disposal of the old battery refer to chapter
.
WARNING