AG03/1
Commissioning English
AG03/1 · Date
23.07.2019 · Art.
No.
86426 · Mod.
status
179/19
40
Dismounting (see
):
1. Unscrew screws
14
.
2. Do not pull the screws out of the cover
15
.
3. Remove the cover
15
incl. the plugged screws
14
with loss protection
21
and light guide
20
axially.
Mounting (see
1. Check the correct position of the O-ring
16
überprüfen. O-ring lie
completely in the groove destined for this purpose.
2. Mounting the cover
15
incl. the plugged screws
14
with loss protec-
tion
21
and light guide
20
. Carefully insert the light guide into the
holes provided in the housing.
Setting mode
Hints for manual setup operation
`
The sense of rotation in manual setup operation does not depend on
the "Sense of rotation" parameter.
`
Manual setup operation is only available in the positioning mode.
`
Profibus: Manual setup operation is only available if the Profibus state
machine is not in the Data Exchange state.
`
CANopen: Manual setup operation is not available in the "OPERA-
TIONAL" or "STOPPED" NMT – states.
`
SIKONETZ5: Manual setup operation is not available in bus operation.
By actuating button
1
or
2
,e.g. with a screwdriver you can start man-
ual setup operation (corresponds ro inching mode Z). For a detailed
description refer to the User manual.
Fig. 10: DIP switch
1
2
1
Right motion = i
2
Left motion = e
NOTICE