Mounting
Instruction Manual FireGuard 2
13542E/4
23
Pos : 51 /Mont age/Tit el 1_M ont age @ 0\ mod_1349349151757_20.doc x @ 7021 @ 1 @ 1
4
Mounting
Pos : 52 /Mont age/Hinweis z ur M ontage FireGuard 2 Vis Guard 2 @ 4\ mod_1436173399790_20.doc x @ 21180 @ @ 1
CAUTION!
Danger of the photometer falling onto the road if improperly mounted.
The following requirements must be met when fastening the instruments in place:
When fastening the photometer, screws with a diameter of at least
M8
must be used.
The material quality of the screws used must correspond to the local mounting and in-
stallation guidelines.
Pos : 53 /Mont age/FireG uard 2/ Allgemeine M ont age FireGuard 2 @ 4\ mod_1436174039813_20.doc x @ 21187 @ 2 @ 1
4.1
General information on mounting the FireGuard 2
Figure 6: Installation position in the air flow
The opening on the sampling point (X) must point in the direction of travel in the tunnel.
The inclination of the photometer must not exceed 20°.
Installation of the measuring system is carried out in the following steps:
WORKSTEP
ADDITIONAL INFO / IMAGES
1.
Mount the photometer at the measuring posi-
tion.
Installation with a variable mounting
bracket 0 .. 90° is made according to Sec-
tion 4.2.
Installation in suspended ceilings is made
according to Section 4.3.
2.
Mount the SIPORT 2 connection box according
to Section 4.6.
3.
Carry out the electrical installation according to
Section 5.