TROUBLESHOOTING
No
Result & SVC Action
Checking flow
1
2
3
4
Reset the unit and Input Test 1 Mode.
(push the button 1 time)
Open the freezer door and Check the air flow.
Check the air temperature. Cold or not?
Check the sensor resistance.
※
The sensor is determined by the
temperature.
For example, 23
㏀
indicates -20
℃
.
3. Troubleshooting With Error Display
18) Poor cooling in Freezer compartment
40
㏀
30
㏀
23
㏀
17
㏀
13
㏀
10
㏀
8
㏀
Result
-22
℉ /
-30
℃
-13
℉ /
-25
℃
-4
℉ /
-20
℃
5
℉ /
-15
℃
14
℉ /
-10
℃
23
℉ /
-5
℃
32
℉ /
0
℃
(1) To (2)
Explain to customer
Check the
Compressor And
sealed system
SVC Action
Cold
Not cold
Status
Go to the 4
Check the Fan
motor(Next page)
SVC Action
Windy
No windy
Status