TROUBLESHOOTING
No
Result & SVC Action
<Temperature table-3>
Checking flow
Short
Open
Normal
Go to the 2
Check the Temp and
resistance(Table-3)
SVC Action
0
Ω
OFF
Other
Result
1
2
Check the Orange(1) to Orange(2).
(Remove Housing)
※
The sensor is determined by the
temperature.
For example, 23
㏀
indicates -20
℃
CON 6
①
Check for a loose connection. (CON6)
②
Check the Pin11(1) to Pin12(2) of CON6.
2. Troubleshooting With Error Display
7) Defrost Sensor Error(dS r)
Short
Open
Normal
Change the sensor
①
Check the Temp and
resistance(Table-3)
②
Check the Harness
PCB to this Joint
SVC Action
0
Ω
OFF
Other
Result
(1) To (2)
Result
40
㏀
30
㏀
23
㏀
17
㏀
13
㏀
10
㏀
8
㏀
-22
℉
/ -30
℃
-13
℉
/ -25
℃
-4
℉
/ -20
℃
5
℉
/ -15
℃
14
℉
/ -10
℃
23
℉
/ -5
℃
32
℉
/ 0
℃