34
34
TROUBLESHOOTING
(1) To (2)
Result
38
㏀
30
㏀
24
㏀
19.5
㏀
15.6
㏀
23
℉
/ -5
℃
32
℉
/ 0
℃
41
℉
/ 5
℃
50
℉
/ 10
℃
59
℉
/ 15
℃
No
Result & SVC Action
<Temperature table-2>
Checking flow
Short
Open
Normal
Change the sensor
Replace the refrigerator
Check the Temp and
resistance(Table-2)
SVC Action
0
Ω
OFF
Other
Result
1
2
Check the Pin21(1) to Pin22(2) of CON7.
※
The sensor is determined by the
temperature.
For example, 30
㏀
indicates 0
℃
CON 7
Check for a loose connection.
2. Troubleshooting With Error Display
4) Refrigerator Sensor Error(rt E)
Содержание UPSXB2627S
Страница 1: ...SERVICE MANUAL BUILT IN SXS REFRIGERATOR Model UPSXB2627S www thesignaturekitchen com MFL67262404 ...
Страница 9: ...9 Circuit Diagram MODEL UPSXB2627S Chapter 3 Circuit Diagram ...
Страница 71: ...EXPLODED VIEW TOP PART 502B 502A 701B 701A 402K 701C 402J 500A 406A 410G ...
Страница 78: ......