41
41
TROUBLESHOOTING
No
Result & SVC Action
Checking flow
(2)~(3)
(1)~(2)
Below 8V
0 or 5V
Change the PCB
Change the motor
SVC Action
Result
1
2
3
4
Open the freezer door and Check the air flow.
※
While an error code is displayed, the fan is
not working.
Check the Fan motor.
Rotate fan using your hand.
It feel sticky, change the motor.
(cause of ice or rust inside of motor)
Check the Fan motor voltage. Pin14(2),
Pin16(3), Pin18(1) of CON6.
CON 6
Reset the unit and Input Test 1 Mode.
(Push the button 1 time)
2. Troubleshooting With Error Display
11) Refrigerator Fan Error(rF E)
Go to 3
Go to 4
SVC Action
No windy
Windy
Status