Micom Function
2-11. Test Function
TEST KEY EXISTS ON PWB ASSY. MAIN BOARD.
MODE
OPERATION
CONTENTS
REMARKS
PRESS TEST BUTTON
ONCE
<Strong Cold mode>
1. CONTINUOUS OPERATION OF COMPRESSOR
AND CONDENSER FAN MOTOR.
2. ALL DEFROST HEATERS TURNS OFF
3. 10 MINUTES IN EARLY STAGE REFRIGERATOR
FAN MOTOR ON
4. AFTER 10 MINUTES ALL FAN MOTORS ON WHEN
THE FREEZER SENSOR IS ABOVE 41¡F AND
REFRIGERATOR SENSOR IS ABOVE 59¡F
5. JUST REFRIGERATOR FAN MOTOR
ON WHEN THE FREEZER SENSOR IS
BELOW 10¡F AND REFRIGERATOR
SENSOR IS ABOVE 35¡F
6. REMAINING CONDITION FREEZER
FAN MOTOR ON
FREEZER FAN MOTOR TURNS OFF
IN FREEZER ROOM DOOR OPENING.
REFRIGERATOR FAN MOTOR TURNS
OFF IN REFRIGERATOR ROOM DOOR
OPENING.
RETURNS TO THE NORMAL MODE
WHEN THE FREEZER DEFROST
SENSOR IS ABOVE 41¡F AND
REFRIGERATOR DEFROST SENSOR IS
ABOVE 64¡F
TEST1
PRESS TEST BUTTON
ONCE AT THE TEST
MODE 1 STATUS
<Forced Defrost
mode>
PRESS TEST BUTTON
ONCE AT THE TEST
MODE 2 STATUS
1. COMPRESSOR OFF
2. ALL FAN MOTORS OFF
3. ALL DEFROST HEATERS ON
RETURNING TO INITIAL STATUS
COMPERSSOR WILL OPERATE AFTER
DELAY FOR 3 MINUTES
4. ALL DISPLAY GRAPHICS TURNS OFF
(ONLY FAILURE CODE INDICATION
PART TURNS ON “22 22” STATUS)
TEST2
NORMAL
STATUS