Technical specifications
13.3 Technical specifications for POM
SIPLUS HCS4200
Operating Instructions, 11/2015, A5E35066204A/RS-AA/002
131
13.3
Technical specifications for POM
product brand name
SIPLUS
Product designation
POM4220 Lowend
POM4220 Midrange
General technical data:
Type of load
Ohmic load
Equipment marking / acc. to DIN EN 81346-2
Q
Supply voltage:
Type of voltage / of the supply voltage
AC
Supply voltage / at AC / rated value
230 V
277 V
Relative negative tolerance / of the supply volt-
age
10 %
25 %
Relative positive tolerance / of the supply volt-
age
10 %
8 %
Supply voltage frequency / 1 / rated value
50 Hz
Supply voltage frequency / 2 / rated value
60 Hz
Relative symmetrical tolerance / of the supply
voltage frequency
5 %
Power capacity
•
of the module / with star connection / at 40
°C / with fan / maximum
16.1 kW
27.7 kW
•
of the module / with star connection / at 40
°C / without fan / maximum
7.3 kW
9 kW
•
maximum permissible
16.1 kW
27.7 kW
Switching capacity current / per phase / maxi-
mum
35 A
50 A
Design of the electrical isolation
Optocoupler and/or protective impedance between main circuit and
PELV
Recovery time / after power failure / typical
1 s
Type of electrical connection / for supply voltage Connector, 3-pin with tension
spring connection
Connector, 3-pin
Type of connectable conductor cross-section
•
for supply voltage / solid
1x (0.2 ... 10 mm²)
1x (0,75 ... 16 mm²)
•
for supply voltage / finely stranded / with core
end processing
1x (0,25 ... 6 mm²)
1x (0,75 ... 16 mm²)
•
for AWG conductors / for supply voltage
1x(24...8)
1x (18 ... 4)