
Commissioning
4.4 Commissioning with factory settings
Frequency inverter
Operating Instructions, 08.10. 2008, t.b.d.
55
Table 4- 2
Factory setting of additional important parameters
Parameter Factory setting
Meaning of the factory setting Function
Access
level
P0003
1
Access to the most frequently
used parameters
Selecting the user access level
1
P0004
0
All parameters are displayed
Parameter filter: filters parameters in
accordance with the functionality
1
P0010
0
Ready to be entered
Commissioning parameter
1
P0100
0
Europe [50 Hz]
Frequency of the regional supply network
•
IEC, Europe
•
NEMA, North America
1
P0300
1
Induction motor
Select the motor type (induction motors /
synchronous motor)
2
P0304
400
[V]
Rated motor voltage
(in accordance with rating plate in V)
1
P0305
depends on the
Power Module
[A]
Rated motor current
(in accordance with rating plate in A)
1
P0307
depends on the
Power Module
[kW/hp]
Rated motor output
(in accordance with the rating plate in kW/hp)
1
P0308
0
[cos phi]
Rated motor power factor (in accordance with
rating plate in cos 'phi') when P0100 = 1.2,
then P0308 is irrelevant
1
P0309
0
[%]
Rated motor efficiency (in accordance with
rating plate in %) when P0100 = 0, then
P0309 is irrelevant
1
P0310
50
[Hz]
Rated motor frequency
(in accordance with rating plate in Hz)
1
P0311
1395
[rpm]
Rated motor speed
(in accordance with rating plate in rpm)
1
P0335
0
Non-ventilated: Shaft-mounted
fan in the motor
Motor cooling (specify the motor cooling
system)
2
P0625
20
°C
Ambient temperature of motor
3
P0640
200
[%]
Motor overload factor (entered in % referred
to P0305)
2
P0700
2 or 6
6 for bus-capable CUs
2 for stand-alone CUs
Select the command source
1
P0727
0
DI0: On / off
DI1: Direction reversal
Control response when the motor starts (start,
stop, reverse)
3
P0970
0
Blocked
Restore factory settings
1
P1000
2 or 6
6 for bus-capable CUs
2 for stand-alone CUs
Select the source of the frequency setpoint
(setpoint input)
1
P1080
0
[Hz]
Minimum frequency
1
P1082
50
[Hz]
Maximum frequency
1
P1120
10
[s]
Ramp-up time
1
P1121
10
[s]
Ramp-down time
1
P1300
0
V/f control with linear
characteristic
Control mode
2
P3900
0
No quick commissioning
Completes the quick commissioning.
1