01.04
Function descriptions
SIEMENS AG 6SG7000-0BA76
9-5
SIMOTRAS HD Operating Instructions
Example 2: The contents of connectors K0401 and K0402 must be output on the connector displays
(parameter r043)
The following settings need to be made to create the correct links:
P044.index.01 = 401: Links connector K0401 to the 1
st
connector display
P044.index.02 = 402: Links connector K0402 to the 2
nd
connector display
Section 8, Sheet G121:
.01
.02
.03
.04
.05
.06
.07
P044 (0)
K
K
K
K
K
K
K
r043.01
r043.02
r043.03
r043.04
r043.05
r043.06
r043.07
401
402
The following values are now displayed in parameter r043:
r043.index.02: Contents of connector K0401
r043.index.02: Contents of connector K0402
r043.index.03: 0
to
r043.index.07: 0
Parameter P044.index.03 to .07 remain at the works setting (0) (value in brackets next to parameter
number) in this example, i. e. the contents of connector K0000 (=fixed value 0) are displayed on
r043.index.03 to .07.
Setting parameters
(see also Section "Data sets")
In addition to the parameters that are used to select a signal (connector, binector), there are also
parameters which define an operating mode or the parameter value of some function.
Representation in function diagrams:
Apart from parameter numbers, the function diagrams may also contain the factory setting, function
and value range of parameters as supplementary information.
P109 (0)
Setting parameter
Parameter number = P109, factory setting = 0
P462.F(10.00s)
(0.01...300.00s)
Ramp-up time
Setting parameter in function parameter set (".F" after parameter number)
Parameter number = P462, factory setting = 10.00s
Value range = 0.01...300.00s
Parameter for setting ramp-up time
Examples:
P700 in function diagram Sheet G113 defines the signal type of the analog input
(voltage input
±
10V, current input 0...20mA, current input 4...20mA).
P705 in function diagram Sheet G113 determines the filter time for the analog input
(adjustable in ms).
Parameters P520 to P530 in Section 8, Sheet G153 determine the shape of the friction
characteristic.
P465 in Section 8, Sheet G126 determines whether the time settings must be multiplied
by a factor of 1 or 60.
Содержание SIMOTRAS 6SG7050
Страница 8: ...Contents 01 04 0 6 Siemens AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 12: ...Safety information 01 04 1 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 30: ...Description 01 04 3 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 32: ...Shipment unpacking 01 04 4 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 46: ...Installation 01 04 5 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 142: ...Start up 01 04 7 56 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 298: ...Function diagrams 01 04 8 156 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 330: ...Function descriptions 01 04 9 32 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 348: ...Faults alarms 01 04 10 18 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 510: ...Parameter list 01 04 11 162 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 570: ...Connectors and binectors 01 04 12 60 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 580: ...Maintenance 01 04 13 10 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 586: ...Servicing Spare parts 01 04 14 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 590: ...Environmental compatibility 01 04 16 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 600: ...Appendix 01 04 18 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 602: ...Appendix 01 04 18 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 603: ......