Start-up
01.04
7-10
SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
7.6.5 Actual speed sensing data
7.6.5.1 Operation with pulse encoder
(often present when retrofitting existing systems)
P083 = 2: The actual speed is supplied by the pulse encoder (K0040)
P140 = 1. Pulse encoder type 1
Encoder with two pulse tracks mutually displaced by 90°
Track 1
X173 28, 29
Track 2
X173 30, 31
P141
Number of pulses of pulse encoder (pulses per revolution)
P142 = 1: Pulse encoder outputs 15V signals
NOTICE
Resetting parameter P142 to the alternative setting does not switch over the supply
voltage for the pulse encoder (terminals X173.26 and 27).
Terminal X173.26 always su15V. An external voltage supply must be
provided for pulse encoders requiring a 5V supply.
P143
Setting the maximum speed for pulse encoder operation (in pulses/rev)
The speed set in this parameter corresponds to an actual speed (K0040) of 100%.
7.6.5.2 Operation with analog tacho
(used in new systems)
P083 = 1: The actual speed is supplied from the “Main actual value” channel (K0013)
(terminals XT.103, XT.104)
P741
Setting of tachometer voltage at maximum speed (approx. 8V to +270.00V)
7.6.6
Speed setpoint data
7.6.6.1 Operation with analog setpoint (U251=0)
P700 = 0: Voltage input (+-10V)
1: Current input (0 to 20 mA)
2: Current input (4 to 20 mA)
P401 Normalization
speed setpoint that must be attained under control by master switch (in %).
with lifting gear: approx. 60%
with travel gear: up to 100%
Note: Limit value for zero-delay angle (U628), see also Section 7.6.14
7.6.6.2 Operation with 4 stage master switch (U251=1)
U251=1: Use setpoint of 4-stage master switch
U665
speed setpoint in “slow” stage
factory setting 10%
U666
speed setpoint in “medium” stage
factory setting 25%
U667
speed setpoint in “fast” stage
factory setting 40%
U668
speed setpoint in “full” stage
factory setting 100%
7.6.7 Selection of basic technological functions
Current limits
P171
System current limit in torque direction I (in% of P100)
P172
System current limit in torque direction II (in% of P100)
Содержание SIMOTRAS 6SG7050
Страница 8: ...Contents 01 04 0 6 Siemens AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 12: ...Safety information 01 04 1 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 30: ...Description 01 04 3 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 32: ...Shipment unpacking 01 04 4 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 46: ...Installation 01 04 5 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 142: ...Start up 01 04 7 56 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 298: ...Function diagrams 01 04 8 156 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 330: ...Function descriptions 01 04 9 32 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 348: ...Faults alarms 01 04 10 18 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 510: ...Parameter list 01 04 11 162 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 570: ...Connectors and binectors 01 04 12 60 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 580: ...Maintenance 01 04 13 10 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 586: ...Servicing Spare parts 01 04 14 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 590: ...Environmental compatibility 01 04 16 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 600: ...Appendix 01 04 18 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 602: ...Appendix 01 04 18 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 603: ......