Function descriptions
01.04
9-20
SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
9.8
Switch over parameter sets
See also in Section 9.1 under heading "Data sets"
WARNING
Parameter sets can be switched over while the converter is in operation (online). As a result,
depending on the setting of the control bits when the motor is running, the configuration or
functions may be altered in such a way as to produce dangerous operating conditions.
For this reason, we strongly recommend that a "basic" parameter set containing all basic
parameter settings is created first and then copied into the other parameter sets (using P055 or
P057) . The intentional changes vis-à-vis the "basic" version should then be entered in each
parameter set.
The "Switch over parameter sets" function affects function parameters (identified by an ".F" next to
parameter number in block diagrams in Section 8) and Bico parameters (identified by a ".B" next to
parameter number in block diagrams in Section 8).
The following operating modes are possible (see also Section 8, Sheet G181):
P649 = 9: The control bits in control word 2 are input bit-serially.
The binectors selected in P676 and P677 determine bits 0 and 1 of control word 2 (= bits
16 and 17 of complete control word), and thus the input of the function data set.
The binector selected in P690 determines bit 14 of control word 2 (= bit 30 of complete
control word), and thus the input of the Bico data set.
P649
≠
9: The connector selected in P649 is used as control word 2.
Bits 0 and 1 of control word 2 (bits 16 and 17 of complete control word) control the input of
the function data set. Bit 14 (= bit 30 of complete control word) controls the input of the
Bico data set.
Control word
Active function data set
Bit 16
Bit17
(active index)
0 0
1
1 0
2
0 1
3
1 1
4
Control word
Active Bico data set
Bit30 (active
index)
0 1
1 2
Caution:
When the "Switch over parameter sets" function is activated, a time delay of up to 25ms may occur
before the newly selected parameter set actually becomes operative.
For information about copying parameter sets, please see Section 11 (Parameter List), parameters
P055 and P057.
Содержание SIMOTRAS 6SG7050
Страница 8: ...Contents 01 04 0 6 Siemens AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 12: ...Safety information 01 04 1 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 30: ...Description 01 04 3 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 32: ...Shipment unpacking 01 04 4 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 46: ...Installation 01 04 5 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 142: ...Start up 01 04 7 56 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 298: ...Function diagrams 01 04 8 156 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 330: ...Function descriptions 01 04 9 32 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 348: ...Faults alarms 01 04 10 18 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 510: ...Parameter list 01 04 11 162 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 570: ...Connectors and binectors 01 04 12 60 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 580: ...Maintenance 01 04 13 10 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 586: ...Servicing Spare parts 01 04 14 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 590: ...Environmental compatibility 01 04 16 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 600: ...Appendix 01 04 18 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 602: ...Appendix 01 04 18 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Страница 603: ......