You can set the inversion via the OctTechnologicalCfg.invertOutput configuration data element
or in the Configuration window of the cam track. The TO must be restarted in order for a change
to be made.
4.2.8
Effect of cam track parameters on mapping
This chapter uses examples to explain the effect of configuration changes on cam track
mapping onto an axis.
See also
Basic mapping of a simple cam track (Page 96)
Advanced mappings with shifted output cam positions (Page 97)
4.2.8.1
Basic mapping of a simple cam track
One cam track with the following data is given.
● Three position-based cams (10-20; 30-50; 60-90)
● Activation mode: Non-cyclical cam track activation
● Start mode and stop mode: Effective immediately
● Track length: 100
● All other user-default variables are the default setting unless another setting is mentioned
explicitly.
Display of given cam track with modified axis reference position, activation mode, and track
length
● Activation mode: Cyclic
● Activation mode: Cyclic
Cam Track TO - Part II
4.2 TO Cam Track basics
Output Cams and Measuring Inputs
96