Diagnostics data
6.1 Diagnostics by means of LED displays
SIMOTION D410
200
Commissioning Manual, 02/2012
Meaning
RDY
RUN/STOP OUT > 5V
SF/BF:
Backing up diagnostic data and non-volatile data (backup running)
x
Λ
(yellow)
x
x
Backing up diagnostic data and non-volatile data (backup completed)
x
Λ
(green)
x
x
1)
Priority of the displays: The displays always visualize the state which is assigned the numerically lowest priority level.
The error of the next highest priority class is displayed after the cause of the previous signal state was eliminated.
2)
The upgrade or downgrade has been completed when the SF/BF LED goes out. The device then starts up automatically
in the upgraded or downgraded configuration (the SF/BF LED display then depends on the operating mode of the
device).
The LED "OUT > 5V" display is controlled only by the encoder evaluation for the integrated
X23 encoder interface in SINAMICS Integrated. The table below lists the display states and
their meaning.
Table 6- 3
LED display OUT > 5V
Status
Meaning
0
Electronic power supply is missing or outside the valid tolerance range. Power supply
≤ 5 V. Use of an encoder with 5 V power supply.
1
(yellow)
Electronics power supply for measuring system available. Power supply >5 V.
Caution: Always ensure that you can operate the encoder on the 24 V power supply (e.g.
HTL encoder). Operating a 5 V encoder on a 24 V supply may cause its electronic
components to be destroyed. This setting can be selected in the expert list of the drive in
parameter p0405.1.
LED in the PROFINET connector (D410 PN only)
Each of the PROFINET ports has both a green LED (LINK) and a yellow LED (ACTIVITY).
The following LED states can occur:
Table 6- 4
Meaning of the LED displays
Name
Color
Status
Meaning
LINK
Green
On
A different device is connected to port x and the physical
connection exists.
ACT
Yellow
Flashing
Data is being received or sent at port x.
Additional references
Detailed information can be found in the
Upgrading SIMOTION Devices Operating
Instructions.