Commissioning (hardware)
2.5 User memory concept
SIMOTION D410
34
Commissioning Manual, 02/2012
See also
Properties of the user memories (Page 34)
Operator actions and their impact on user memory (Page 37)
2.5.2
Properties of the user memories
Non-volatile data
Non-volatile data is used with the objective of retaining user- and system-relevant data when
SIMOTION D410 is in de-energized state. You will find information about the area that can
be used for non-volatile data in the
SIMOTION SCOUT Configuration Manual.
Non-volatile data available in SIMOTION devices:
Table 2- 1
Content of non-volatile data
Non-volatile data
Content
Kernel data
•
Last operating state
•
IP parameters (IP address, subnet mask, router address)
•
DP parameters (PROFIBUS DP address, baud rate)
•
Diagnostics buffer
Retain variables
•
Variables in the interface or implementation section of a unit declared
with VAR_GLOBAL RETAIN
•
Global device variables set with the "RETAIN" attribute
Retain TO
Absolute encoder offset
DCC blocks
SAV blocks and user-defined blocks with retain behavior.
("SAV = SAVE", blocks for the non-volatile data backup)
Note
DCC SIMOTION blocks with retain behavior act like retain variables in terms of copying RAM
to ROM, performing a memory reset, downloading, backing up non-volatile SIMOTION data
(_savePersistentMemoryData), and backing up data such as retain variables.
With DCC SINAMICS blocks, data are only backed up using FRAM, i.e. not
_savePersistentMemoryData.
For additional details, please refer to the
DCC Programming Programming Manual.
The SIMOTION D410 backed-up data have the following features: