Commissioning (software)
4.2 Configuring the system in offline mode
SIMOTION D410
Commissioning Manual, 02/2012
83
8.
Confirm your entries with "OK". The data will be written to the CompactFlash Card.
9.
Remove the CF card and insert it in the D410 slot.
10.
Switch on the D410. The D410 starts with the downloaded project.
Note
The components' firmware is automatically updated, depending on the FW version on the
SINAMICS components and on the CompactFlash Card. During an FW update, please
take note of the messages and alarms in the SIMOTION SCOUT detail window. An FW
update on the SIMOTION D410 is indicated by the RDY LED flashing yellow, while on the
DRIVE-CLiQ components (TM, SMC, etc.) it is indicated by the RDY LED flashing
red/green.
•
FW update running: RDY LED flashes slowly (0.5 Hz)
•
FW update complete: RDY LED flashes quickly (2 Hz)
Go offline once all the FW updates are complete, then switch the 24 V supply for the
upgraded initialization components off/on.
4.2.6
Downloading the project incl. sources and additional data
Overview
In the case of SIMOTION V4.1 SP2 and higher, it is possible to download additional data
(e.g. sources) to the target device when saving a project to the CompactFlash Card or
downloading to the SIMOTION D410. These data are required for:
●
Online object comparison (e.g. additional properties)
●
Various detailed comparisons (e.g. ST source file comparison)
●
Synchronization with online objects.
In order to be able to load a project's sources and additional data to the PG, this must be
specified in the project under "Options" > "Settings" > "Download" > "Store additional data on
the target device". Alternatively, this setting can also be made when the data is loaded to the
target device/target system.
You can, for example, perform a project comparison with the sources and additional data
stored on the CompactFlash Card (see example below).
Project comparison (example)
You intend to carry out servicing work on a commissioned system and have placed a project
on your PC/programming device. This project is not consistent with the project on the
SIMOTION D410 in the system. In order to analyze the differences, perform an object
comparison via "Start object comparison".