Commissioning (software)
4.16 Deleting data
SIMOTION D410
154
Commissioning Manual, 02/2012
4.16.5
Restoring the default settings of SIMOTION D410
Overview
SIMOTION D410 is supplied with default parameters such as the transmission rate or
PROFIBUS addresses. You can restore the default settings using the DIL switch. This
deletes the following data:
●
Non-volatile SIMOTION data in the SIMOTION device
●
The backup copy of non-volatile SIMOTION data on the CompactFlash Card
(PMEMORY.XML/PMEMORY.BAK)
●
User data in the "volatile SIMOTION data" area and on the CompactFlash Card
●
The communication configuration (IP and DP parameters) on the CompactFlash Card is
set to the factory settings.
All licenses on the CompactFlash Card are retained.
Restoring the default settings using the DIL switch
1.
The power supply is shut down.
2.
Select the MRES operating mode by
–
Setting mode selector switches S1 to S3 to OFF AND
–
Using the service selector switches to ensure that no service functions are selected
(S4 to S7 = OFF).
(See figure below.)
6ZLWFKVHWWLQJ 21
6ZLWFKVHWWLQJ 2))
0RGHVHOHFWRUVZLWFK
6WR6
6HUYLFHVHOHFWRUVZLWFK
6WR6
21
Figure 4-42
MRES switch position
3.
Restart the power supply.
The SIMOTION user data is deleted. The default settings are loaded. SIMOTION D410
remains in STOP mode.
4.
Change to the required mode by setting the DIL switch.
Note
The default communications parameters are now restored. You must re-configure the
communication parameters of SIMOTION D410.