Configuring with Web Based Management
6.3 "Wizard" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
99
●
DCP Server
Specify whether or not the device can be accessed with DCP (Discovery and
Configuration Protocol):
–
"-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
–
Read/Write
With DCP, device parameters can be both read and modified.
–
Read Only
With DCP, device parameters can be read but cannot be modified.
●
SNMP
Select the protocol from the drop-down list. The following settings are possible:
–
"-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
–
SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
–
SNMPv3
Access to device parameters is possible with SNMP version 3. You can configure
other settings in " System > SNMP > General".
●
SNMPv1/v2 Read-Only
Enable or disable write access to SNMP variables with SNMPv1/v2c.
●
SINEMA configuration interface
If the SINEMA configuration interface is enabled, you can download configurations to the
device via the TIA Portal.