Configuring with Web Based Management
6.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
260
Configuration Manual, 08/2018, C79000-G8976-C267-13
Description
The table has the following rows:
●
State
Shows the status of the C-PLUG. The following are possible:
–
ACCEPTED
There is a C-PLUG with a valid and suitable configuration in the device.
–
NOT ACCEPTED
Invalid or incompatible configuration on the inserted C-PLUG.
–
NOT PRESENT
No C-PLUG is inserted in the device.
–
FACTORY
C-PLUG is inserted and does not contain a configuration. This status is also displayed
when the C-PLUG was formatted during operation.
–
MISSING
No C-PLUG is inserted. Functions are configured on the device for which a license is
required.
●
Device Group
Shows the SIMATIC NET product line that used the C-PLUG or KEY-PLUG previously.
●
Device Type
Shows the device type within the product line that used the C-PLUG or KEY-PLUG
previously.
●
Configuration Revision
The version of the configuration structure. This information relates to the configuration
options supported by the device and has nothing to do with the concrete hardware
configuration. This revision information does not therefore change if you add or remove
additional components (modules or extenders), it can, however, change if you update the
firmware.