10-5
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
The axis travels until a signal change from 0 to 1 takes place at the digital
input. This triggers two reactions:
S
A block change on-the-fly, and thus immediate processing of block N20.
S
Storage of the actual position at the time of this signal change to “Actual
value block change.” This position is also the starting position for any
subsequent chain-measure programming.
Depending on the situation, N20 is processed as follows:
S
If the block position in N20 is less than the actual position at the time
when the digital input is received (reversal of direction), the equipment is
stopped so that the position can then be approached in the opposite direc-
tion.
S
If no position is programmed in block N20, movement is braked, the
functions programmed in N20 are executed, and processing then moves
on to the next block (except if the block contains M0, M2 or M30).
S
If the programmed path in block N20 is less than the deceleration dis-
tance, the programmed position is overshot and then positioned by a re-
versal of direction.
If no signal change occurs at the digital input, the target position of N10 is
approached, with the following additional response:
When the target position is reached, the error message “Digital input not ac-
tuated” is output (see Table 11-5, Class 2 No. 15).
The “Set actual value on-the-fly” function is programmed and triggered by a
digital input; the block change occurs on the fly and the actual value is set to
a new dimension (programmed coordinate) at the same time. The digital in-
put must be parameterized with the “Set actual value on-the-fly” function by
way of machine data item MD34.
Notes to the
Example of
External Block
Change
Set Actual Value
On-the-fly G87,
G88, G89
Writing Traversing Programs
Содержание SIMATIC FM 453
Страница 6: ...vi FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Preface ...
Страница 14: ...xiv FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Table of Contents ...
Страница 28: ...2 4 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Basic Principles of Positioning ...
Страница 96: ...5 34 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Defining Parameters of the FM 453 ...
Страница 316: ...10 20 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Writing Traversing Programs ...
Страница 358: ...A 6 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Technical Specifications ...
Страница 372: ...C 4 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 List of Abbreviations ...
Страница 378: ...Index 6 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Index ...