9-9
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
9.1.3
General Handling Information
Before data/settings can be transferred to the FM 453, an operating mode
must be active (e.g. “Jogging” mode = 1 and MODE = 1). That means that
communication with the FM 453 has been initiated and the FM 453 has ac-
cess to valid machine data.
Operating Modes
(codes)
Relevant
Control Signals
Relevant
Checkback Signals
Required Data/
Settings
Job No.
Jogging (01)
[R+], [R–], [STP], [AF],
[OVERR], [BP] = 1 or 2
[BL], [SFG], [FR+], [FR–],
[SYN], [WFG]
1, 10 (servo enable)
Open-loop control (02)
[R+], [R–], [STP], [AF],
[OVERR], [BP] = 1 or 2
[BL], [SFG], [FR+], [FR–],
[WFG]
2
Reference point approach
(03)
[R+], [R–], [ST], [STP], [AF],
[OVERR]
[BL], [SFG], [FR+], [FR–],
[WFG], [SYN], [PEH]
10 (servo enable)
Incremental relative (04)
[R+], [R–], [STP], [AF],
[OVERR], [BP] = 1...100 for
increment table or 254
[BL], [SFG], [FR+], [FR–],
[WFG], [SYN], [PEH]
1, 10 (servo enable), 3
(only if BP = 254, if BP
= 1...100 the appropriate
increments must be
parameterized)
MDI (06)
[ST], [STP], [AF], [QMF],
[OVERR]
[BL], [SFG], [FR+], [FR–],
[WFG], [SYN], [PEH],
[AMF), [MNR], [T-L]
6, 10 (servo enable)
Automatic (08)
Automatic single block
(09)
[ST], [S]), [EFG], [STP], [AF],
[QMF], [OVERR]
[BL], [SFG], [FR+], [FR–],
[WFG], [SYN], [PEH],
[AMF], [T-L], [PBR],
[MNR]
17 (assuming the corre-
sponding traversing pro-
gram was parameter-
ized),
10 (servo enable)
Error condition:
S
Message via BF/FS – acknowledgement with BFQ/FSQ
S
Message via DF – acknowledgement on next correct data transfer
S
Message via diagnostic interrupt – acknowledgement on “Restart” (job
no. 11)
Here are a few hints for starting a movement and about the response of the
FM 453 to a change of the status of the S7-400 CPU:
It is assumed that the FM 453 has been parameterized correctly.
S
First a mode must be set. The servo enable must subsequently be set in
order to prevent the axis from “running away,”.
S
Before starting a movement in a mode, first transfer the appropriate refer-
ence data (e.g., speed levels with write job 1); the override must be > 0.
Overview
Hints to the User
Description of Functions
Содержание SIMATIC FM 453
Страница 6: ...vi FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Preface ...
Страница 14: ...xiv FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Table of Contents ...
Страница 28: ...2 4 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Basic Principles of Positioning ...
Страница 96: ...5 34 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Defining Parameters of the FM 453 ...
Страница 316: ...10 20 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Writing Traversing Programs ...
Страница 358: ...A 6 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Technical Specifications ...
Страница 372: ...C 4 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 List of Abbreviations ...
Страница 378: ...Index 6 FM 453 Servo Drive Step Drive Positioning Module C79000 G7076 C453 01 Index ...