04/99
Programming Preparations
Getting Started with C7-621-AS-i
21
Save your data block
DB1
by clicking on the
icon in the toolbar.
In the application the following addresses in DB1 are significant:
Adress
Symbol
Status format
Meaning
0.0
M1_IN1
Bin
Optical Bero
0.1
M1_IN2
Bin
Inductive Bero
1.0
M3_IN1
Bin
Position switch
2.0
M5_IN2
Bin
ON button
2.1
M5_IN3
Bin
Acknowledgment button
2.3
M5_IN1
Bin
OFF button
4.0
M1_OUT1
Bin
Belt ON (bit memory)
6.0
M5_OUT1
Bin
Green lamp
6.1
M5_OUT2
Bin
Red lamp
6.2
M5_OUT3
Bin
White lamp