04/99
Program Example
Getting Started with C7-621-AS-i
57
Network 4 : Operating mode display
A
DB1.DBX4.0
// Belt ON
=
DB1.DBX6.0
// Green lamp on casing
=
M 21.0
// Message flag
FC2 : Eject conditions
Network 1 : Count
A
DB1.DBX1.0
// Position switch
A
DB1.DBX4.0
// Belt ON
A
DB1.DBX0.1
// Inductive Bero
FP
M30.0
// Rising edge
CV
C1
// Count forward
L
C1
// Transfer count to DB46.DBW2
T
DB46.DBW2
AN
C1
// Count = 0
A
DB1.DBX4.0
// Belt ON
L
C#0
// Write preset count
S
C1
// Initialize counter
L
DB46.DW2
// If the value in DB46.DW2 is greater than
L
DB46.DW0
// the maximum value set, the counter
>I
R
C1
// is reset
Network 2 : Parcel sequence
A
DB1.DBX4.0
// Belt_ON
A
DB1.DBX0.0
// Opto_Bero: parcel
FN
M30.1
// Edge formation
L
S5T#10S
// Parcel interval at least 10 seconds
SE
T5
// Pulse extension
A
T5
// Parcel interval too small
A
DB1.DBX0.0
// Opto_Bero: parcel
FP
M30.2
// Edge formation
S
M21.1
// Fault in parcel sequence
Network 3 : Display: parcel detected
A
DB1.DBX4.0
// Belt ON
A
DB1.DBX0.0
// Opto_Bero
=
DB1.DBX6.2
// Lamp: parcel detected
=
M 21.3
// Message flag
Network 4 : Stop-monitoring
A
DB1.DBX4.0
// Belt ON
A
DB1.DBX1.0
// Parcel at end of belt
L
S5T#5S
// Monitoring time 5 seconds
SD
T3
// ON delay
A
T3
S
M21.2
// Fault in parcel stop