ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 61 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
7
Troubleshooting and error messages
An error message from the file handler always has the same format. The presence of an error is always
indicated in the status byte (5th byte) of the acknowledgement telegram. It is 4 bytes long and in ASCII
format.
Acknowledgement with error:
’x’
CC Status ADB
DBN DBL
00
xx
xxxx
xxxx
0
1
2/3
4
5
6/7
8/9
10
xxxx
04
01
11/14
Error number: 000 ... 999
Error group:
A = Protocol error
B = SLG error
C = MDS error
D = Task related error
E = Directory error
F = File related error
K = Error in the OUEUE-WRITE command
Error code
When terminated within a block sequence the block in which the
error was detected is shown here.
A block sequence will automatically be interrupted by an error
Error flag is set (Bit 0 in status byte = 1)
The error flag must always be interrogated by the user
Command code showing where the error occurred
In general:
– An error terminates block creation
– There are no “ignore” or “retry” options
– A “RESET” is not necessary following an error
– The parameters ADB and DBN contain the block number in which the error occurred
– If using the LOAD command:
a LOAD command should be programmed after each error
(As a rule, the directory in the ASM is invalid if the error occurred during a directory
operation. If the error occurred in the data area, the directory in the ASM remains val-
id. If many errors occur, however, the user cannot know exactly whether the error oc-
curred during the DIR processing or while processing the user data).