![Siemens MOBY I ASM 421 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/siemens/moby-i-asm-421/moby-i-asm-421_technical-description_377253060.webp)
ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 58 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
B
EAKO = 1; The user assumes control of the MDS. No MDS is in the transmission window of the
SLG on restart. Processing of the MDS takes place statically. The process consists of the
commands: read “file A”, read “file B” and write “file C”.
1.
After restart and RESET from the user, the file handler has the status 11 .
2.
The user detects the presence of a new MDS via a proximity switch connected to a digital input
(DI) and stops the conveyor. At the same time, the file handler detects a new MDS: ANW
bit = 1. The file handler begins processing the MDS: the SLG no. is written to the MDS. The
file handler changes to status 3 .
3.
The user begins to process the commands : The command READ “file A” is sent to the ASM
and is started by the file handler: Status 27 .
4.
Acknowledgement of command READ “file A” sent to the user: status 3 .
5.
Command READ “file B” to ASM: status 27 .
6.
Acknowledgement of command READ “file B” sent to the user: status 3 .
7.
Command WRITE “file C” to ASM: status 27 .
8.
Acknowledgement of command WRITE “file C” sent to the user: status 3 . The user has
now completed the processing of the MDS and restarts the conveyor.
9.
The MDS leaves the transmission window of the SLG: ANW bit = 0; status 5 .
10. The user detects the presence of an MDS via a proximity switch on DI and stops the conveyor.
At the same time, the file handler recognizes the presence of a new MDS: ANW bit = 1;
status 1 .
11.
The user begins to send off the commands: the command READ “file A” is sent to the ASM.
The file handler begins processing by writing the SLG no. to the MDS. Finally the READ com-
mand is issued: status 27 .
12. This point is identical to point 4. The MDS processing cycle restarts from the beginning.
Status diagram for this application, as long as no error occurs:
11
27
3
5
1
3
A
B
C