![Siemens MOBY I ASM 421 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/siemens/moby-i-asm-421/moby-i-asm-421_technical-description_377253026.webp)
ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 24 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
3.4.2
CREATE
A new file is established on the MDS by the CREATE command. An entry will be made in the MDS directo-
ry for each CREATE command. DIR and FAT in the MDS will be updated.
Telegram to the file handler:
00H
→
No attribute
01H
→
Read only; the file can only be read
02H
→
Write once; the data may only be written once. New data can
be appended. The file cannot be erased with DELETE. The
data must be written using the automatic append function.
’B’
CC CI ADB DBN DBL
xx 00 0000
0001
0CH
F.name
Attribute
Data length to be res.
0
1
2/3
4
5
6/7
8/9
10
11/18
19
20/22
File name; 8 ASCII characters (20H - 7EH)
The file handler reserves the file length given here. If
000000H is given as the data length, the file handler
reserves a block as standard procedure.
Note:
Specification of a data length is not mandatory. If the data
written later exceeds the data length given here, the file
handler will automatically reserve more memory for the
file. MDS memory is managed dynamically by the file
handler.
Setting of access rights for this file:
’I’
0001
Acknowledgement:
’B’
CC Status ADB DBN DBL
00 xx 0000
0001
0
1
2/3
4
5
6/7
8/9
10
00
0001 00