![Siemens MOBY I ASM 421 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/siemens/moby-i-asm-421/moby-i-asm-421_technical-description_377253011.webp)
ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 9 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
2.3
Setting the mode of operation
Switch bank S1:
4
5
3
2
ON
1
7
8
6
ON
OFF
=
^
=
^
1 = Proximity message from ASM;
(Z-message)
0 = no proximity message
Access rights of this ASM station
00
01
Step “D” (= Delete); all commands allowed
10 Step “W” (= Write); Formatting of MDS and
deletion of files are not allowed
11 Step “R” (= Read only); only read operations on
the MDS are allowed
0 = Siemens file handler is set up
1 = reserved for 8-E41
1 = Master
0 = Slave
1 = odd parity
0 = even parity
Baud rate:
00 =
9600 Baud
01 =
4800 Baud
10 = Reserved for 38.4 KBaud
11 = 19200 Baud
Setting of the
3964R procedure
to the user
“1”
“0”