ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 22 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
The maximum block length (maximum length of a telegram segment) can be set using the RESET com-
mand. The default value for the block length is 128. The maximum block length that can be set is 255.
The blocking sequence can be aborted using the RESET command. The blocking sequence will be en-
ded. No further acknowledgement of the aborted command will be issued.
All other commands within a blocking sequence will be rejected by the ASM 421 with an error message.
The present status of the blocking sequence remains unchanged.
3.4
File handler commands
The following table lists all file handler commands
Command
CC
Purpose
Prio
*
Telegram format (to ASM)
FORMAT
W
Format and initialize MDS
RWD
WD
00 00 0000
’I’
0001 0001 0C
Volume
Type
Parameter
’I’
I
D
CREATE
Create file on MDS
B
WD
WRITE
Write part or complete file
R
READ
Read data from file
D
D
DELETE
Delete file
WD
Y
ATTRIB
Set file attribute
RWD
G
DIR
Read MDS directory
RWD
S
ASM-STATUS
Read ASM status
RWD
F
MDS-STATUS
Read MDS status
RWD
X
RESET
Reset command to ASM
RWD
N
NEXT
Process the next MDS
RWD
T
TRACE
MDS absolute read
RWD
Z
Presence
Proximity message from ASM
00 00 0000 ’B’
0001 0001 0C
F.name
Attr.
res. length
’I’
00 00 0000 ’W’
ADB 0001 DBL
F.name
Adr.
Leng.
’I’
Data
00 00 0000 ’R’
0001 0001
0E
F.name
Adr.
Leng.
’I’
00 00 0000 ’D’
0001 0001
08
F.name
’I’
00 00 0000 ’Y’
0001 0001
09
F.name
Attr.
’I’
00 00 0000 ’G’
0001 0001
00
’I’
00 00 0000 ’S’
0001 0001
00
’I’
00 00 0000 ’F’
0001 0001
00
’I’
00 00 0000 ’X’
0001 0001
07
’I’
00 00 0000 ’N’
0001 0001
00
’I’
00 00 0000 ’Z’
0001 0001
05
00 00 00 00
ANW
00
00 00 0000 ’T’
0001 0001
06
Startadr
’I’
Leng.
00 00 0000 ’U’
ADB 0001 DBL
F.name
Adr.
Leng.
’I’
Data
U
WD
UPDATE
Update complete file
00 00 0000 ’L’
ADB 0001 DBL Leng.
’I’
Data
L
RWD
LOAD
Transmit directory to ASM
00 00 0000 ’M’
0001 0001
00
’I’
M
RWD
MOVE
Retrieve directory from ASM
Mode EAKO ECC No. Prior. Reg.
**
D
QUEUE-WRITE
Set up complete data carrier
Q
00 00 0000 ’Q’
ADB 0001 DBL Option
Res
Leng
’I’
Data
Res
D
C
COVER
Protect MDS structure
00 00 0000 ’C’
0001 0001
09
Volume
User
’I’
RWD
E
QUEUE-READ
Read complete data medium
xx 00 0000 ’E’
0001 0001 DBL
Option
Res
Leng.
’I’
Data
RWD
H
Startup message
Reported by ASM when
power returns
00 00 0000 ’H’
0001 0001
00
00
**
*
The priority and access rights of the interface module are switch selectable (see section 2.3).
**
This message is from ASM only. Switch 8 must be on as described in section 2.3.