ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 42 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
3.4.15
RESET
Telegram to the file handler:
’X’
CC CI ADB DBN DBL
00
xx
0000
0001
RESET mode
EAKO
SLG No.
0
1
2/3
4
5
6/7
8/9
10
11
12
16
Max. telegram length;
the file handler will not send an
acknowledgement telegram that
exceeds the length given here.
Range of values:
64 ...
254
0
= Sets the default value of
128 bytes
If the data length exceeds the
max. block length, the data will be
transmitted in block form (see
section 3.3)
at present always ’0’
’I’
0001 07
ECC
14/15
SLG number of this ASM/SLG station:
the value entered here will be placed in the system
area of the MDS before command processing be-
gins. It forms an important feature of the entry/exit
checking. If an MDS moves outside the field and
comes back, the file handler knows that it is the old
MDS that has just been processed.
Range of values:
0000
= reserved
0001 ... FFFE
= normal SLG no.
Important:
Each SLG in a system must
have a different SLG number.
FFFF
= Test function:
The next MDS can be the same
one despite the NEXT com-
mand.
’0’
= ECC disabled (default)
’1’
= ECC mode
A description and function of ECC (error correction code)
can be found in the FB 250 description.
Prior.
Block length
13
17
Type of entry/exit checking (1 byte, ASCII)
’0’
= MDS recognition by field scanning; NEXT command is man-
’1’
= Without entry/exit control; timeout on ASM 421
’2’
= MDS control via 1 DI and field scanning (see section 5.3)
’3’
= MDS control via 2 DIs (see section 5.4)
’4’
= Without entry/exit control (see section 5.5)
’5’
= Special operating mode: If the check sum changes, system
area may only be written, no NEXT (see section 5.6)
’B’
= Break (hard reset); all MDS actions are immediately aborted. Data in the
MDS may possibly no longer be consistent
’C’
= Close (soft reset); The command currently being processed will be termi-
nated and the directory updated. The data in the MDS are guaranteed to be
consistent. The acknowledgement of the soft reset may be delayed.
’X’
00
xx
0000
0001
RESET mode
EAKO
SLG No.
’I’
0001 07
ECC
Prior.
Block length
Or
t
ABTAST
Scanning interval for
presence check (for
operation of MDS
507/407E,
see page 43)