3.4.12
TRACE
The TRACE command provides a physical dump of the MDS memory. It can be very useful for test pur-
poses. The selected type of entry / exit checking is irrelevant as far as this command is concerned. It is
always executed immediately.
If a data block that exceeds the maximum telegram length is to be read, the data will be transmitted in
blocks. Refer to the example in section 3.4.5 to see how the blocking function works.
Telegram to the file handler:
’T’
CC CI
ADB
DBN DBL
xx
00
0000
0001
0
1
2/3
4
5
6/7
8/9
10
0001
06
’I’
Start addr.
xxxxxxH
11/13
Length
14/16
xxxxxxH
Length of the data to be read (3 bytes hex)
Physical start address in the MDS of the data to be
read (3 bytes hex)
Acknowledgement:
’T’
CC Status ADB
DBN DBL
00
xx
0000
0001
0
1
2/3
4
5
6/7
8/9
10
0001
xx
00
Data
11/254
Data
If data length > telegram length:
the file handler calculates ADB and sends the value to the user in the first
acknowledgement telegram
The TRACE command is the only file handler command that does not return an error indicator in the
acknowledgement when processing an MDS that is not formatted (but is initialized). In each case the
acknowledgement contains the physical MDS addresses.
The ECC mode should be set correctly with the RESET command before using the TRACE command.