![Siemens MOBY I ASM 421 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/siemens/moby-i-asm-421/moby-i-asm-421_technical-description_377253057.webp)
ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 55 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
5.6
Special Operating Mode (Test Operation)
EAKO = ’5’
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉ
ÉÉ
ÉÉ
Prox. switch I
Direction of
movement of
MDS
MDS
Prox. switch II
ÉÉ
ÉÉ
ÉÉ
Computer
or PC
ASM 421
SLG
Dig. inputs
ANW
In this mode of operation absolutely no checking of MDS entry/exit is carried out by the file handler. The
MDS control must be handled entirely by the user.
If a command is issued to the file handler, it will be stored until an MDS arrives in the transmission window
of the SLG. The file handler then commences the processing of the command. When executing com-
mands that do not change the DIR + FAT structure (i.e. no change to the checksum), the system area is
not updated. This increases the processing speed in especially time-critical applications, e.g. ECC oper-
ation of EEPROM MDS.
Operating with EAKO 5 automatically precludes the use of the NEXT command.
Note:
The use of EAKO 5 is a special mode of operation and it should therefore be regarded as test
operation.