![Siemens MOBY I ASM 421 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/siemens/moby-i-asm-421/moby-i-asm-421_technical-description_377253035.webp)
ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 33 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
Example:
Five files are to be read from the MDS.
'E'
KK KI ADB
DBN DBL
xx 00 0000
0001
0
1
2/3
4
5
6/7
8/9
10
0001 54H
'I'
0000
000000
000046H
11/12
13/21
22/24
Option
In reserve Length
1st subtelegram on
filehandler:
25 to 94
Data
File entries
= 5 file entries = 14 + 5 * 14
= 5 file entries = 5 * 14
'E'
KK Status ADB
DBN DBL
00 xx 0000
0003
0
1
2/3
4
5
6/7
8/9
10
0001 F4H
00
11 to 254
Data (244 bytes)
Acknowledgment:
File data
'E'
KK KI ADB
DBN DBL
xx 00 0000
0003
0
1
2/3
4
5
6/7
8/9
10
0002 00
'I'
2nd subtelegram on
filehandler:
'E'
KK Status ADB
DBN DBL
xx 00 0000
0003
0
1
2/3
4
5
6/7
8/9
10
0002 F4H
00
11 to 254
Data (244 bytes)
Acknowledgment:
Con't: File e data
'E'
KK KI ADB
DBN DBL
xx 00 0000
0003
0
1
2/3
4
5
6/7
8/9
10
0003 00
'I'
3rd subtelegram on
filehandler:
'E'
KK Status ADB
DBN DBL
00 xx 0000
0003
0
1
2/3
4
5
6/7
8/9
10
0003 0CH
00
11 to 22
Data (12 bytes)
Acknowledgment:
Con't: File e data
The total length of the data sent to the user can be calculated from the sum of all DBLs.
F4H + F4H + 0CH = 1F4H
→
Decimal: 500 bytes
The user data must be analyzed to obtain the data length of the individual files.