![Siemens MOBY I ASM 421 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/siemens/moby-i-asm-421/moby-i-asm-421_technical-description_377253016.webp)
ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 14 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
Example of a daisy-chain configuration (see 2.4.1)
CP
or
Computer
passive
+ SE
– SE
+ EM
– EM
4
7
0
+24 V
4
7
0
+24 V
active
passive
passive
.......
470
470
.......
*
*
*
*
*
*
dig.
inputs
*)
This line must be looped through from the computer to the last ASM!
SLG
ASM 421 No. 1
ASM 421 No. 2
ASM 421 No. 4
b16
b4
b6
z6
z4
b4
b6
z6
z4
b4
b6
SLG
SLG
z4
z4
b32
b32
Request
dig.
out–
puts
Select
z16
b16
z16
b16
z16
Where possible, the computer should handle the active part of the TTY interface, in which case the resis-
tors shown on ASM no. 1 will not be needed.
If this is not possible (as shown in the diagram), the active part of the interface must be simulated in the
connector of ASM no. 1 using 4 resistors (R = 470 Ohm).
The numbers in the diagram refer to pins in the 48-way female connector.
Note:
With this cabling, all the wired ASMs must actually be connected, otherwise the circuit will
remain open!