6AW5451-6XX01-1K
ES 030-K Manual
3 - 2
Subject to change without prior notice
RD: 08.2000
(4)J31069-D0136-U001-A0-7618
3.2
Description of the Blocks
3.2.1
Data Block (DB)
Following a system start, there are 120 DBs each containing
256 DWs present in the ES 030-K RAM (DB1 - DB120).
These DBs can be utilised by the user program without having
been parameterized in the program (e.g. as input buffer for
MOBY, bar code, etc.). While receiving data, block limits can be
exceeded; i.e. with a telegram length of more than 512 byte
user data, the user data will automatically be written into the
following DB. The data blocks which have been parameterized
in the user program, are transferred into RAM after system
start; they may not exceed 256 data words.
The data block 1 up to DW 99 is allocated to the system;
beginning with DW 100 it can be utilised by the user. The
allocation for data block DB1 is described in the following.
Allocation of Data Block 1
Hardware clock
(in ASCII format)
Mask to be displayed (see also Chapter 3.4.2)
Keyboard / s = Shift level (see also Chapter 3.4.1)
Receive serial interface or SINEC L1 slave
with extended buffer length; error in DW 74)
with extended buffer length)
transmit
with extended buffer length; error in DW 74)
Receive expansion serial interface
with extended buffer length; error in DW 75)
with extended buffer length)
transmit
with extended buffer length; error in DW 75)
Data
Word
No.
0
1
2
3
4
5
6
7
8
9
10
11 - 40
41
42
43
(43
44
(44
45
46
(46
47
48
49
(49
50
(50
51
52
(52
Data Word
Left Byte
Data Word
Right Byte
Meaning
Res.
Res.
Position of DIP
switch
Year
Month
Day
Hours
Minutes
Seconds
DB
Key 1 - 30
Baud r./Bus-No.
DB
Error
DB
Error
Baud rate
DB
Error
DB
Error
S1 on motherboard (see also Chapter 5.1)
(Entry after voltage return)
actual number
Number of bytes
max.number
Number of bytes
actual number
max. number
Res.
Res.
Year
Month
Day
Hours
Minutes
Seconds
DW
Number of bytes
Key 1s - 30s
Driver
DW
max. number
actual number
DW
Number of bytes
Driver
DW
max. number
actual number
DW
Number of bytes
DIP-switch
Clock
Display
Keyboard
serial
interface
Expansion
serial
interface