6AW5451-6XX01-1K
ES 030-K Manual
Subject to change without prior notice
2 - 3
RD: 08.2000
(4)J31069-D0136-U001-A0-7618
2.2.7
MOBY-M
Up to two MOBY-M options can be plugged into the
ES 030-K. The various LBS (reader/transmitter stations) can
then be connected to these options.
Data carriers with capacities of 64 bytes, 2 Kbytes, 8 Kbytes, as
well as mixed code and ROMs are available. (On the 8-Kbyte
data carrier, only 2 Kbytes can be read/written to; on the mixed
code data carrier, only the variable part can be read/written to).
Further information about MOBY-M components can be
found in the manual (order no. 6AW5450-8XX00-0K).
The LBS can be supplied internally or externally with 24 V. If
supplied internally, the 24 V voltage separation is cancelled.
2.2.8
MOBY-I
Up to two MOBY-I options can be plugged into the ES 030-K.
The various SLGs (write/read devices) can then be connected
to these options.
Data carriers with capacities of 62 byte RAM, 32 Kbyte RAM,
128 byte EEPROM, and 8 Kbyte EEPROM are available.
Further information about MOBY-I components can be found
in the MOBY-I catalogue (order no.
E86060-K6910-A101-A2). The SLG can be supplied
internally or externally with 24 V. If supplied internally, the 24 V
voltage separation is cancelled.
File Handler
The MOBY-I option
“
F" contains the MOBY-I file handler.
With this option, the user data to the MDS can be processed
using logical filenames. The user does not have to administrate
the physical addresses on the MDS. The file handler in the ES
030-K is compatible with the MOBY-I interface modules
ASM 421 and ASM 401.
2.2.9
MOBY-L
Up to two MOBY-L options can be plugged into the
ES 030-K. The SLG (write/read device) is then connected to
these options.
Data carriers with capacities of 128 byte EEPROM and 512
byte EEPROM are available.
Further information about MOBY-L components can be
found in the MOBY-L catalogue (order no.
E86060-K6920-A101-A1). The SLG can be supplied
internally or externally with 24 V. If supplied internally, the 24 V
voltage separation is cancelled.
2.2.10
PROFIBUSDP
A PROFIBUSDP module can be connected to either connec
tor 3 or connector 4 of the ES 030K.
A standard, 9way, subminiature D plug connector is used for
the connection to the bus system.
The connector of the ES 030K also provides the voltage sup
ply for the bus connection.
The baud rate of the PROFIBUSDP is recognized automati
cally. A baud rate of up to 1.5 Mbaud is possible.
Additional information on the subject of the PROFIBUSDP
and its configuration is available in various catalogues and ma
nuals. Examples: SINEC Industrial Communication Networks
(IK10 catalogue), (E86060K6710A101A57600) and ET 200
Distributed I/O System (6ES5 8956SE22).
2.2.11
Power Supply
The power supply of the ES 030-K has been designed for
connection to either 230 V AC or, in a special version, to
24 V DC. The AC version contains a filter in order to suppress
voltage transients on the mains voltage.
Calculating the Current Requirements -24V
The ES 030-K provides a floating voltage of 24 V/400 mA. This
voltage is used to internally supply the MOBY, the digital
inputs/outputs, and the serial interfaces.
The following current capacities are required:
MOBY-M
LBS 11, 21, 41
100 mA
LBS 31, 32, 71
50 mA
MOBY-I
SLG 41
90 mA
SLG 42
180 mA
SLG 43
250 mA
SLG 44
80 mA
MOBY-L
SLG 52
120 mA
Serial interface
TTY
active
40 mA
passive
0 mA
Digital input
5 mA
Digital output
each input
depending on load
max. 100 mA
It must be observed that the maximum current is not exceeded.
2.2.12
Memory Expansion
The user has an EEPROM area of 16 K available for
instructions. The programs and data blocks (data blocks
which do not require presettings do not have to be
programmed) to be loaded share this area.
The RAM area is designated for data blocks and includes
DB 1 to DB 120, containing 256 data words each.