ECO REFERENCE MANUAL
14-2
D-R
208/240V MICROMASTER Eco:
Screened cable
F
max
= 16kHz
Current (I/I
N
)
ECO1-110/2
ECO1-150/2
ECO1-220/2
ECO1-300/2
ECO1-400/2
Cable length (m)
1.5
200
200
155
150
145
1.4
200
200
200
200
200
1.3
200
200
200
200
200
1.2
200
200
200
200
200
1.1
200
200
200
200
200
1.0
200
200
200
200
200
380V/500V MICROMASTER Eco:
Un-screened cable
F
max
= 4kHz
Current
(I/I
N
)
ECO1-110/3
ECO1-150/3
ECO1-220/3
ECO1-300/3
ECO1-400/3
ECO1-550/3
ECO1-750/3
Cable Length (m)
440V
550V
440V
550V
440V
550V
440V
550V
440V
550V
440V
550V
440V
550V
1.5
110
180
110
100
170
165
165
160
200
200
200
200
200
200
1.4
120
110
120
110
175
170
170
165
200
200
200
200
200
200
1.3
130
115
130
115
175
170
170
165
200
200
200
200
200
200
1.2
140
120
140
120
175
170
170
165
200
200
200
200
200
200
1.1
150
130
150
130
175
170
170
165
200
200
200
200
200
200
1.0
160
140
160
140
175
170
170
165
200
200
200
200
200
200
380V/500V MICROMASTER Eco:
Screened cable
F
max
= 4kHz
Current
(I/I
N
)
ECO1-110/3
ECO1-150/3
ECO1-220/3
ECO1-300/3
ECO1-400/3
ECO1-550/3
ECO1-750/3
Cable Length (m)
440V
550V
440V
550V
440V
550V
440V
550V
440V
550V
440V
550V
440V
550V
1.5
80
70
80
70
140
140
135
135
200
200
200
200
200
200
1.4
85
80
85
80
145
145
140
140
200
200
200
200
200
200
1.3
95
80
95
80
145
145
140
140
200
200
200
200
200
200
1.2
100
80
100
80
145
145
140
140
200
200
200
200
200
200
1.1
100
80
100
80
145
145
140
140
200
200
200
200
200
200
1.0
100
80
100
80
145
145
140
140
200
200
200
200
200
200