ECO REFERENCE MANUAL
12-3
EMC
Filter Part Numbers:
Inverter Model No.
Class A Filter Part No.
Class B Filter Part No.
Standard
ECO1-110/2 - ECO1-150/2 (IP20 only)
6SE3290-0DB87- 0FA3
6SE3290-0DB87-0FB3
EN 55011 / EN 55022
ECO1-220/2 - ECO1-400/2 (IP20 only)
6SE3290-0DC87- 0FA4
6SE3290-0DC87-0FB4
EN 55011 / EN 55022
ECO1-110/3 - ECO1-150/3
6SE3290-0DA87- 0FA1
6SE3290-0DA87-0FB1
EN 55011 / EN 55022
ECO1-220/3 - ECO1-300/3 (IP20 only)
6SE3290-0DB87- 0FA3
6SE3290-0DB87-0FB3
EN 55011 / EN 55022
ECO1-400/3 - ECO1-750/3 (IP20 only)
6SE3290-0DC87- 0FA4
6SE3290-0DC87-0FB4
EN 55011 / EN 55022
ECO1-110/2 - ECO1-400/2 (IP56 only)
6SE3290-0DG87- 0FA5
6SE2100-1FC20
EN 55011 / EN 55022
ECO1-550/2
6SE3290-0DG87- 0FA5
6SE2100-1FC20
EN 55011 / EN 55022
ECO1-750/2
6SE3290-0DH87- 0FA5
6SE2100-1FC20
EN 55011 / EN 55022
ECO1-1100/2 - ECO1-2200/2
6SE3290-0DJ87- 0FA6
6SE2100-1FC21
EN 55011 / EN 55022
ECO1-3000/2 - ECO1-4500/2
6SE3290-0DK87- 0FA7
EN 55011 / EN 55022
ECO1-300/3 - ECO1-1500/3 (IP56 only)
6SE3290-0DG87- 0FA5
6SE2100-1FC20
EN 55011 / EN 55022
ECO1- 1100/3 - ECO1-1500/3
6SE3290-0DG87- 0FA5
6SE2100-1FC20
EN 55011 / EN 55022
ECO1-1850/3 - ECO1-2200/3
6SE3290-0DH87- 0FA5
6SE2100-1FC20
EN 55011 / EN 55022
ECO1-3000/3 - ECO1-4500/3
6SE3290-0DJ87- 0FA6
6SE2100-1FC21
EN 55011 / EN 55022
ECO1-5500/3 - ECO1-9000/3
6SE3290-0DK87- 0FA7
EN 55011 / EN 55022
Maximum mains supply voltage when filters are fitted is 460V.
Three classes of EMC performance are available.
These levels of performance are
only achieved when using the
default switching frequency (or
less) and a maximum screened
motor cable length of 25 m.
Class 1: General Industrial
Compliance with the EMC Product Standard for
Power Drive Systems EN 61800-3 for use in
Second Environment (Industrial) and Restricted
Distribution.
EMC Phenomenon
Standard
Level
Emissions:
Radiated Emissions
EN 55011
Level A1 *
Conducted Emissions
EN 61800-3
*
Immunity:
Electrostatic Discharge
EN 61000-4-2
8 kV air discharge
Burst Interference
EN 61000-4-4
2 kV power cables, 1 kV control
Radio Frequency Electromagnetic Field
IEC 1000-4-3
26-1000 MHz, 10 V/m
* Emission limits not applicable inside a plant where no other consumers are connected to the same