8.3
Calibration
Precondition
It is only possible to calibrate the camera measuring system if:
• A program has already been set up
• All the parameters have been correctly set
- and -
• Detection of the reflector is functioning without errors throughout the entire measuring
range
Calibrating the camera system
Note
Calibrating the camera measuring system after installation
To achieve a high measurement reliability and accuracy, you need to calibrate the camera
measuring system after installation.
The calibration determines the zero position of the reflector that is dependent on the hoisting
height. For this purpose, the reflector is measured at two different hoisting heights.
Note
Calibration of the main reflector
The calibration relates exclusively to the main reflector and does not depend on whether an
additional reflector is installed.
Parameterization
8.3 Calibration
SIMOCRANE CenSOR
86
Operating Instructions, 07/2021