Menu command
or parameter
Description
Match
Not relevant for CenSOR
Good evaluation
Fair evaluation
Poor evaluation
Trigger too fast
Trigger interval
• Time interval between two trigger pulses (format: hh:mm:ss.ms)
• Min.: Minimum of the trigger intervals since the last startup (format:
hh:mm:ss.ms)
• Max.: Maximum of the trigger intervals since the last startup (format:
hh:mm:ss.ms)
• Average: Average of the trigger intervals since the last startup (format:
hh:mm:ss.ms)
Cycle time
• The currently required cycle time
For the program currently being output:
the time from the internal trigger to the end of processing minus the time in
which the image is buffered.
• Min.: Minimum of the processing times since the last startup
• Max.: Maximum of the processing times since the last startup
• Average: Average of the processing times since the last startup
• Too short: Absolute and relative number of image processing procedures in
which the set upper limit of the cycle time was exceeded.
X position
X position of the center point of the main reflector relative to the center of the
image. Normalized to the full resolution for the current image.
Y position
Y position of the center point of the main reflector relative to the center of the
image. Normalized to the full resolution for the current image.
Rotation angle
Rotation angle of the center point of the main reflector for the current image (cor‐
responds to a counterclockwise rotation).
Viewing angle
Not relevant for SIMOCRANE CenSOR MV540 H
Distance to border Not relevant for SIMOCRANE CenSOR MV540 H
Resetting the statistical information
Note
Program change results in reset of statistical information
Note that a program change results in a reset of the statistical information.
Use the "Reset statistics" button to reset all statistical information.
Note that this button is only visible if the logged-in user has administrator rights (see "Settings"
→ "Security").
Parameterization
8.2 Application
SIMOCRANE CenSOR
74
Operating Instructions, 07/2021
Содержание 6GA7202-2AA10-1BF1
Страница 2: ......
Страница 8: ...Table of contents SIMOCRANE CenSOR 6 Operating Instructions 07 2021 ...
Страница 10: ...Introduction SIMOCRANE CenSOR 8 Operating Instructions 07 2021 ...
Страница 62: ...Commissioning 7 3 Setting up the camera SIMOCRANE CenSOR 60 Operating Instructions 07 2021 ...
Страница 142: ...Technical data 11 5 Retro reflective reflector 500x500 SIMOCRANE CenSOR 140 Operating Instructions 07 2021 ...
Страница 158: ...Appendix A 3 Standards and certifications SIMOCRANE CenSOR 156 Operating Instructions 07 2021 ...