4.5.3
Storage
Storing outdoors
NOTICE
Damage to the motor
Damage can occur if incorrectly stored.
Take all precautions to protect the motor under extreme climatic conditions, e.g. salt-laden
and/or dusty, moist/humid atmospheres.
Choose a dry storage location which is safe from flooding and free from vibration. Repair
any damage to the packaging before putting the equipment into storage if this is necessary
to ensure proper storage conditions. In order to ensure protection against ground moisture,
locate machines, equipment and crates on pallets, wooden beams or foundations. Prevent
equipment from sinking into the ground. Do not impede air circulation under the stored
items.
Covers or tarpaulins used to protect the equipment against the weather must not come into
contact with the surfaces of the equipment. Use wooden spacer elements to ensure that air
can circulate freely around the equipment.
Storing indoors
The storage rooms must provide protection against extreme weather conditions. They must be
dry, free from dust, frost and vibration and well ventilated.
Bare metal surfaces
For transport, the bare surfaces (shaft ends, flange surfaces, centering edges) should be coated
with an anti-corrosion agent which will last for a limited amount of time (<6 months). Apply
suitable anti-corrosion measures for longer storage times.
Condensation drain hole
Open any condensation drain holes to drain the condensation depending on the environmental
conditions, every six months at the latest.
Storage temperature
Permissible temperature range: -20 °C to +50 °C
Maximum permissible air humidity: 60%
For machines that have a special design regarding the ambient temperature in the operating
state or the installation altitude, other conditions could apply regarding the storage
temperature. In this case, refer to the machine rating plate for data on the ambient
temperature and installation altitude.
Preparing for use
4.5 Transport and storage
1LE5, 1PC4 shaft heights 280 ... 355
Operating Instructions, 11/2022, A5E41454666A
37
Содержание 1LE5
Страница 2: ......
Страница 116: ...Maintenance 9 4 Corrective maintenance 1LE5 1PC4 shaft heights 280 355 114 Operating Instructions 11 2022 A5E41454666A ...
Страница 130: ...Spare parts 10 9 Exploded drawings 1LE5 1PC4 shaft heights 280 355 128 Operating Instructions 11 2022 A5E41454666A ...
Страница 134: ...Disposal 11 6 Disposal of components 1LE5 1PC4 shaft heights 280 355 132 Operating Instructions 11 2022 A5E41454666A ...
Страница 141: ......