13.Install the outer bearing cover, if available.
14.Install the sealing elements:
9.4.3
Mounting dimension "x"
Mounting dimension "x" of V rings
Shaft height
x
mm
280 ... 355
13.5 ±1.2
Standard design
9
Special design
9
• Extreme caution and attention to the correct positioning are vital during installation and
assembly.
• Make sure the sealing surface is free of dirt and damage.
• Lightly grease the sealing lips.
9.4.4
Fan
9.4.4.1
Metal fan disassembly
Metal fan
• Shaft height 63: Release the two M4 clamping screw so that the fan can rotate freely on the
shaft.
• Shaft heights 71...90: Release the M5 set screw so that the fan can rotate freely on the shaft.
• Shaft height 100...355: Remove the locking ring.
• Use a suitable tool to pull off the fan (puller).
• Locate the arms of the pulling tool in the openings in the fan in the vicinity of the hub.
• Alternatively, place the pulling tool at the outer edge of the fan plate.
• Uniformly withdraw the fan from the shaft by turning the pressure screw of the pulling tool.
Maintenance
9.4 Corrective maintenance
1LE5, 1PC4 shaft heights 280 ... 355
110
Operating Instructions, 11/2022, A5E41454666A